For your own peace of mind, Print a copy of this form and follow the step by step questions. Upon completion, you will have  a better understanding of the Electrical condition of your home. If, after you are finished, you still have questions or concerns, feel free to call upon us for help or assistance.

ComEd meter outside securely attached to wall -----------------------------------------Yes  (    )  No  (    )

Pipe goes up from meter to ComEd line and secured to the wall-----------------------Yes  (    )  No  (   )

Main Electrical Panel has -----------------------------------------------Circuit Breakers  (    )   Fuses  (    )

Main Breaker installed -------------------------------Yes  (    )  No  (    )   Size of Breaker: __________

Number of breakers installed: =  __________  -- Number of blank spaces available: =  ___________

Ground wire attached from panel to Cold water pipe -----------------------------------Yes  (    )  No  (    )

Breakers labeled as per their use --------------------------------------------------------Yes  (    )  No  (    )  

All Outside outlets and Bathroom outlets GFCI protected: ------------------------------Yes  (    )  No  (    )

All Outlets in kitchen with-in five (5) foot of sink GFCI protected:-----------------------Yes  (    )  No  (    )

Smoke detectors installed outside each bedroom and on each floor: -----------------Yes  (    )  No  (    )

Carbon Monoxide detector located on each floor: --------------------------------------Yes  (    )  No  (    ) 

Outlets throughout house of Grounded type: --------------------------------------------Yes  (    )  No  (    )

Are there at least two (2) circuits for the kitchen------------------------------------------Yes  (    )  No  (    )

Are Micro Wave, Dishwasher, Garbage Disposal on separate breakers: ------------Yes  (    )  No  (    ) 

Kitchen Range is: --------------------------------------------------------------------- Gas  (    )   Electric  (    )

Cloths Dryer is: ----------------------------------------------------------------------- Gas  (    )   Electric  (    )

Do you have Central Air Conditioning --------------------------------------------------- Yes  (    )  No  (    )

Are Extension cords used for appliances or other items-------------------------------  Yes  (    )  No  (    )

ESTIMATED HOUSE USE AND LOAD

Square foot of house times 3  (use outside dimension of house)   _______ sq. ft X 3 =  ________ watts

Small appliance circuits (per Code) --------------------------------------------------- =           3,000     watts

Bathroom and Laundry circuits per code ---------------------------------------------- =           3,000    watts

Electric Range ( if applicable use 8,000 watts ----------------------------------------- =   __________ watts

Electric Dryer ( if applicable use 4,500 watts ------------------------------------------ =  __________ watts

 Central Air Conditioner (If applicable use 4,500 watts ) ----------------------------- =  __________  watts

                                                                             Total Watts ------------------------ =  _____________

Total Watts: ____________ divided by 220 Volts = _________________  Total House Amps

IS THIS TOTAL AMP LOAD SMALLER THAN YOUR MAIN BREAKER  ----------- Yes  (    )  No  (    )